Features:
* Low Insertion Loss
* High Quality and Reliability
Applications:
* High Speed Networks
* Coherent Deteching
* Fiber Sensors
* Research
Specifications:
Parameters | Unit | Values | ||
Channel Number | 4 | |||
Center Wavelength | nm | ITU Grid | ||
Filter Type | 200GHz | 100GHz | ||
Channel Passband(0.5dB) | nm | c 0.25 | c 0.11 | |
Insertion Loss | dB | ≤1.5 | ||
Isolation | Adjacent | dB | ≥30 | |
Non-adjacent | dB | ≥40 | ||
Polarization Dependent Loss | dB | ≤0.3 | ||
Min. Extinction Ratio at 23°C | dB | ≥20 | ||
Min Return Loss | dB | ≥50 | ||
Thermal Stability | dB/℃ | ≤0.005 | ||
Max. Optical Power (CW) | mW | ≥500 | ||
Fiber Length | M | ≥1 | ||
Fiber Type | PM Panda Fiber, 900um jacket | |||
Operating Temperature | ℃ | -5 to +75 | ||
Storage Temperature | ℃ | -40 to +85 | ||
Dimension | mm | 29x10x6.5 |
* Above specifications are for device without connector.
* For devices with connectors, IL will be 0.3dB higher, RL will be 5dB lower and ER will be 2dB lower.
* The PM fiber and connector key are aligned to the slow axis.
Package Dimension:
Ordering Information:
4PMUCDWDM—①—②②—③③③—④④—⑤⑤
Channel Spacing | ITU Grid | Fiber Jacket | Fiber Length | Connector Type |
1 - 100 GHz 2 - 200 GHz | 21-C21-28 23-C23-30 SS- Specify | 250-250um Bare Fiber 900-900um Loose Tube S-Specify | 07 - 0.7m 10 – 1.0m S - Specify | 1-FC/UPC 2-FC/APC 3-SC/UPC 4-SC/APC N-None S-Specify |