广告

西门子CPU模块6ES7288-1ST30-0AA1

  • 图片0
  • 图片1
  • 图片2
  • 图片3
  • 图片4
  • 图片5
1/6
新浪微博
QQ空间
豆瓣网
百度新首页
取消

西门子CPU模块6ES7288-1ST30-0AA1
西门子CPU模块6ES7288-1ST30-0AA1
Active Line Connection Modules‑2 comprise a Line Connection Module, an Active Interface Module in chassis‑2 format and an Active Line Module in chassis‑2 format installed in a cabinet system. They can supply motoring energy to the DC link and return regenerative energy to the line supply.

The Active Line Connection Module‑2 contains the line-side infeed via main switch and circuit breaker and pre-charging circuit. It connects the line-side supply network and the Active Line Module in chassis‑2 format. It is equipped as standard with a radio interference suppression filter according to EN 61800-3 Category C3.

Active Line Connection Modules‑2 generate a controlled DC voltage that is kept consistent regardless of fluctuations in the line voltage (the line voltage must lie within the permissible tolerances).

In the factory setting, the DC voltage is regulated to 1.5 times the rms value of the nominal voltage of the distribution system.

Active Line Connection Modules draw a virtually sinusoidal current from the supply system and cause virtually no line harmonics.

Active Line Connection Modules are suitable for connection to supply systems grounded at the neutral point (TN, TT) and non-grounded (IT) supply systems. The following voltages and currents are available:

Line voltage

Rated infeed/regenerative feedback current

Rated power

380 ... 480 V 3 AC

560 ... 1405 A

355 ... 900 kW




设计
Active Line Connection Modules‑2 always include an Active Interface Module in chassis‑2 format, which contains the associated Clean Power Filter and pre-charging circuit. The line filter that is included ensures compliance with the EMC requirements for the "second environment".

Active Line Connection Modules‑2 are available for installing the Motor Modules to the right (article number "...RE0") and for installing the Motor Modules to the left (article number "...LE0"). The Line Connection Module with the line connection is installed directly next to the Active Interface Module.

Depending on the input current, the following versions are available:

≤ 800 A: Main circuit breaker with fuse switch disconnector
> 800 A: Circuit breaker, type 3WL, with option L25 as draw-out circuit breaker
Parallel connection for power increase
The power rating can be increased by connecting Active Line Connection Modules‑2 in parallel. You must observe the following rules:

Up to 6 identical Active Line Connection Modules‑2 can be connected in parallel.
Option M88 must be ordered so that the infeed can be realized at the common DC link.
A common Control Unit is required whenever the modules are connected in parallel. For more than 4 power units, these must be distributed as symmetrically as possible between at least two DRIVE-CLiQ ports (e.g. 3 x 2 Active Line Connection Modules‑2 in series or at least 2 x 3 Active Line Connection Modules‑2 in series).
The parallel connection must be supplied from a common infeed point, i.e. the modules cannot be operated on different line supplies
A derating factor of 5 % must be taken into consideration, regardless of the number of modules connected in parallel.
The main contactors or circuit breakers of the respective Line Connection Modules must close together and simultaneously. Monitoring is performed via the -X50 terminals of the respective Line Connection Module
For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.


集成


Connection example of an Active Line Connection Module‑2 (Line Connection Module)



Connection example of an Active Line Connection Module‑2 (Active Interface Module in chassis‑2 format and Active Line Module in chassis‑2 format)


技术规范
Line voltage 380 ... 480 V 3 AC

Active Line Connection Modules‑2





6SL3731-7TE35-6RE01)

6SL3731-7TE36-4RE01)

6SL3731-7TE37-5RE01)

6SL3731-7TE38-4RE01)





6SL3731-7TE35- 6LE01)

6SL3731-7TE36-4LE01)

6SL3731-7TE37-5LE01)

6SL3731-7TE38-4LE01)

Rated power











At IN DC (50 Hz 400 V)
kW

355

400

450

500

At IL DC (50 Hz 400 V)
kW

300

350

400

450

At IN DC (60 Hz 460 V)
hp

500

550

650

700

At IL DC (60 Hz 460 V)
hp

400

500

550

650

DC link current











Rated current IN DC
A

630

710

835

940

Base-load current IL DC 2)
A

571

649

760

854

Maximum current Imax DC
A

857

974

1140

1281

Infeed/regenerative feedback current











Rated current IN I
A

560

635

745

840

Maximum current Imax I
A

773

878

1028

1155

Pulse frequency

kHz

4

4

4

4

Current demand











24 V DC auxiliary power supply
A

1.5

1.5

1.5

1.5

230 V 1 AC
A

4.1

4.1

4.1

4.1

DC link capacitance











Active Line Module
μF

16450

16450

18800

18800

Drive line-up, max.
μF

250000

250000

250000

250000

Power loss, max. 3)











at 50 Hz 400 V
kW

12.14

12.65

16.38

17.32

at 60 Hz 460 V
kW

12.14

12.65

16.38

17.32

Cooling air requirement

m3/s (ft3/s)

1.3 (45.9)

1.3 (45.9)

1.3 (45.9)

1.3 (45.9)

Sound pressure level LpA 4)

(1 m) at 50/60 Hz

dB

75/75

75/75

75/75

75/75

Line supply connection

L1, L2, L3



4 x M12

4 x M12

10 x M12

10 x M12

Conductor cross-section, max. (IEC)
mm2

8 × 240

8 × 240

8 × 240

8 × 240

PE/GND connection



PE bar

PE bar

PE bar

PE bar

Busbar cross-section
mm2

600

600

600

600

Conductor cross-section, max. (IEC)
mm2

240

240

240

240

Cable length, max. 5)

Shielded/unshielded

m (ft)

3900/5850 (12795/19193)

3900/5850 (12795/19193)

3900/5850 (12795/19193)

3900/5850 (12795/19193)

Degree of protection

(standard version)



IP20

IP20

IP20

IP20

Dimensions

(standard version)











Width
mm (in)

1600 (63.0)

1600 (63.0)

1600 (63.0)

1600 (63.0)

Height
mm (in)

2200 (86.6)

2200 (86.6)

2200 (86.6)

2200 (86.6)

Depth
mm (in)

600 (23.6)

600 (23.6)

600 (23.6)

600 (23.6)

Weight, approx.

(standard version)

kg (lb)

989 (2180)

994 (2191)

1191 (2626)

1192 (2628)

Frame size











Line Connection Module


HL

HL

JL

JL

Active Interface Module


FS2

FS2

FS4

FS4

Active Line Module


FS2

FS2

FS2+

FS2+

Rated short-circuit current according to IEC

kA

50

50

100

100

Minimum short-circuit current 6)

kA

18

18

2

2



1) Article number "...RE0": Motor Modules installed to the right, "...LE0": Motor Modules installed to the left.

2) The base-load current IL DC is based on a duty cycle of 115 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s.

3) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

4) Total sound pressure level of Active Interface Module and Active Line Module.

5) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual. The cable lengths are valid for use in IT systems. When used in TN systems, the cable lengths are shortened to 30 % of the specified value. When used in the TN system and when operating with increased pulse frequency, you will obtain the permitted cable lengths upon request.

6) Current required for reliably triggering protective devices.

Line voltage 380 ... 480 V 3 AC

Active Line Connection Modules‑2





6SL3731-7TE38-8RE01)

6SL3731-7TE41-0RE01)

6SL3731-7TE41-2RE01)

6SL3731-7TE41-3RE01)

6SL3731-7TE41-4RE01)





6SL3731-7TE38-8LE01)

6SL3731-7TE41-0LE01)

6SL3731-7TE41-2LE01)

6SL3731-7TE41-3LE01)

6SL3731-7TE41-4LE01)

Rated power













At IN DC (50 Hz 400 V)
kW

560

630

710

800

900

At IL DC (50 Hz 400 V)
kW

500

560

630

710

800

At IN DC (60 Hz 460 V)
hp

800

900

1050

1150

1300

At IL DC (60 Hz 460 V)
hp

700

800

900

1000

1150

DC link current













Rated current IN DC
A

1010

1100

1245

1415

1575

Base-load current IL DC 2)
A

915

1004

1131

1287

1431

Maximum current Imax DC
A

1373

1506

1697

1931

2147

Infeed/regenerative feedback current













Rated current IN I
A

900

985

1110

1260

1405

Maximum current Imax I
A

1238

1358

1530

1740

1935

Pulse frequency

kHz

4

4

4

4

4

Current demand













24 V DC auxiliary power supply
A

1.5

1.5

1.5

1.5

1.5

230 V 1 AC
A

4.1

4.1

4.1

4.1

4.1

DC link capacitance













Active Line Module
μF

25900

25900

25900

40800

40800

Drive line-up, max.
μF

250000

250000

250000

250000

250000

Power loss, max. 3)













at 50 Hz 400 V
kW

17.70

18.55

19.62

23.9

26.5

at 60 Hz 460 V
kW

17.70

18.55

19.62

23.9

26.5

Cooling air requirement

m3/s (ft3/s)

1.7 (60.0)

1.7 (60.0)

1.7 (60.0)

1.7 (60.0)

1.7 (60.0)

Sound pressure level LpA 4)

(1 m) at 50/60 Hz

dB

75/75

75/75

75/75

75/75

7575

Line supply connection

L1, L2, L3



10 x M12

10 x M12

10 x M12

10 x M12

10 x M12

Conductor cross-section, max. (IEC)
mm2

8 × 240

8 × 240

8 × 240

8 × 240

8 × 240

PE/GND connection



PE bar

PE bar

PE bar

PE bar

PE bar

Busbar cross-section
mm2

600

600

600

600

600

Conductor cross-section, max. (IEC)
mm2

240

240

240

240

240

Cable length, max. 5)

Shielded/unshielded

m (ft)

3900/5850 (12795/19193)

3900/5850 (12795/19193)

3900/5850 (12795/19193)

3900/5850 (12795/19193)

3900/5850 (12795/19193)

Degree of protection

(standard version)



IP20

IP20

IP20

IP20

IP20

Dimensions

(standard version)













Width
mm (in)

1800 (70.9)

1800 (70.9)

1800 (70.9)

1800 (70.9)

1800 (70.9)

Height
mm (in)

2200 (86.6)

2200 (86.6)

2200 (86.6)

2200 (86.6)

2200 (86.6)

Depth
mm (in)

600 (23.6)

600 (23.6)

600 (23.6)

600 (23.6)

600 (23.6)

Weight, approx.

(standard version)

kg (lb)

1264 (2787)

1345 (2965)

1406 (3100)

1509 (3326)

1529 (3371)

Frame size













Line Connection Module


JL

JL

JL

JL

JL

Active Interface Module


FS4

FS4

FS4

FS4

FS4

Active Line Module


FS4

FS4

FS4

FS4+

FS4+

Rated short-circuit current according to IEC

kA

100

100

100

100

100

Minimum short-circuit current 6)

kA

2

2.5

2.5

3.2

3.2



1) Article number "...RE0": Motor Modules installed to the right, "...LE0": Motor Modules installed to the left.

2) The base-load current IL DC is based on a duty cycle of 115 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s.

3) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

4) Total sound pressure level of Active Interface Module and Active Line Module.

5) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual. The cable lengths are valid for use in IT systems. When used in TN systems, the cable lengths are shortened to 30 % of the specified value. When used in the TN system and when operating with increased pulse frequency, you will obtain the permitted cable lengths upon request.

6) Current required for reliably triggering protective devices.

浔之漫智控技术(上海)有限公司为你提供的“西门子CPU模块6ES7288-1ST30-0AA1”详细介绍
在线留言

*详情

*联系

*手机

西门子PLC模块代理商信息

VIP推荐信息

热门搜索

PAC/PL>可编程自动化>西门子CPU
信息由发布人自行提供,其真实性、合法性由发布人负责;交易汇款需谨慎,请注意调查核实。
触屏版 电脑版
@2009-2024 京ICP证100626