IECEX出口欧洲IE3效率隔爆型电动机YE3-315S-4-110KW400V
3.2 使用条件
3.2 Service conditions
3.2.1 环境空气温度随季节而变化,但不超过40℃,环境空气低温度为-15℃。
3.2.1 Ambient air temperature varies with the season, it is not allowed to exceed 40 ℃, the minimum temperature of ambient air is -15℃.
3.2.2 海拔不超过1000m。
3.2.2 The altitude is not allowed to be more than 1000m.
3.2.3 环境空气湿月月平均高相对湿度为90%,同时该月月平均低温度不25℃。
3.2.3 The monthly average maximum relative humidity of the wettest month is 90%, at the same time, the monthly average minimum temperature of the month is 25 ℃.
3.2.4 额定电压为380V、660V、1140V、380V/660V、660V/1140V。
3.2.4 The rated voltages are 380V, 660V, 1140V, 380V/660V, 660V/1140V.
3.2.5 额定频率为50Hz。
3.2.5 The rated frequency is 50Hz.
3.2.6 电动机的定额是以连续工作制(S1)为基准的连续定额,允许满压起动。
3.2.6 The rating of the motor is a continuous rating based on the continuous working system (S1), full-voltage starting is allowed.
3.2.7 电动机采用F级绝缘,定子绕组的温升(电阻法)按80K考核(其中机座号315L的2、4极和机座号355,允许按105K考核)。
3.2.7 The motor adopts Class F insulation, and the temperature rise of the stator winding (resistance method) is assessed according to 80K (the number 2 pole and number 4 pole of frame number 315L and the frame number 355 can be assessed by 105K).
4 电动机的安装结构型式及主要规格
4 Installation Structure Type and Main Specifications of the Motor
4.1 本系列电动机的结构及安装型式件表2。
4.1 The structure and installation type of this series of motors are shown in Table 2.
表2
Table 2
机座号
Frame number 结构及安装代号IM
Structure and installation code IM
80~112 B14、B34、V18
80~160 B3、B5、B6、B7、B8、V1、V3、V5、V6、V15、V35、V37
80~355 B35
180~280 B3、B5、V1
315~355 B3、V1
出口欧洲电机 隔爆型电动机 欧洲马达 IECEX认证马达 出口电机 卧式马达 ATEX认证